For masonry fixing into concrete, brick and stone, this Fixaball heavy duty shield anchor pairs an M10 threaded loose hex bolt with a masonry shield. It has a zinc finish and a high tensile 8,8 specification, with a 16mm shield hole size and installation data provided for accurate fitting.
Suitable where a secure mechanical anchor fixing is required, the bolt is tightened with a 17mm spanner and installed to the stated depth and torque values.
Available options
- Maximum fixing thickness: 10mm
- Maximum fixing thickness: 25mm
- Maximum fixing thickness: 50mm
- Maximum fixing thickness: 75mm
Key features
- M10 thread diameter
- Zinc finish
- High tensile 8,8
- Suitable for concrete, brick and stone
Specifications
- Shield hole size: 16mm
- Hole diameter: 16
- Hole depth: 65
- Fixture/material clearance hole: 11 – 12
- Centre spacing between holes: 180
- Minimum distance from edge of material: 120
- Tensile/pull load: 6. 2 k/N (tonnes)
- Shear load: 6. 1 k/N (tonnes)
- Torque to tighten: 27 Nm
- Socket size guide: M10 - 17mm spanner
Safety information
- Clean the hole using an appropriate sized brush before installation.
- Installation temp is 0; make sure water does not seep into the hole, as expansion from water to ice could crack the concrete.
- Under wet conditions, use a specified injection resin.
- Introduce the anchor through the material to be fixed into the hole up to the embedment depth according to the stated values, and use a hammer to ensure the required depth.
- Do not apply any intermediate layer between the material to be fixed and the washer, including sealing products.
- Apply the specified torque with a torque wrench.
- If the holes on the material to be fixed have a bigger diameter than required, insert a thicker washer of a bigger diameter. This procedure does not ensure correct distribution of shear loads amongst all anchors of the same group, and the shear load is applied only to anchors with a correct diameter on the material to be fixed.
- When drilling holes, respect the specified minimum depth and diameters.
- Holes must be square to the surface of the base material for safety during installation.
- If rebar is encountered, abort the hole, repair with high quality mortar, and create a new hole no less than twice the diameter of the shield anchor away.